Experimental Analysis Of Different Proportions Of Polypropylene Fiber On Concrete
Description
Plain concrete a very low tensile strength, limited ductility and little resistance to cracking internal micro cracks are inherently present in the concrete & its poor tensile strength is due to the propagation of such micro cracks, eventually leading to the brittle fracture of the concrete. The principle reason for incorporating fibers into a cement matrix is to increase the toughness and tensile strength, and improve the cracking deformation characteristics of the resultant composite. In order for fiber reinforced concrete (FRC) to be a viable construction material, it must be able to compete economically with existing reinforcing systems.
Details
First of all, the core materials to compose the concrete were gathered in order to organize the synthetic Fiber Reinforced Concrete (SFRC) test. Therefore, the main components like Cement, Sand, Fine Aggregates, Water, and Synthetic Fibers were put into utilization in this rest.
Materials:
- Cement:
The type of cement used in this test was Portland Cement Type-I, from the manufacturers of Fauji Cement.
The cement had a fineness modulus of 3128 cm2/gm along with the initial setting time of 90 minutes and the final setting time of 222 minutes. the percentage of consistency was 29.25%, and the specific gravity was 3.03. However, there was no expansion in the soundness test.
- Fine Aggregates:
The fine aggregates were also passed through a number of tests including analyzing its fineness modulus, sieve analysis, specific gravity and water absorption.
- Coarse Aggregates:
The same tests were performed for the coarse aggregates that were previously performed on the fine aggregates. Readings like fineness modulus, Sieve Analysis, Specific Gravity and Water Absorption were also calculated for coarse aggregates for further procedures.
- Water:
Normal Tap Water from the facility of CUI WAH Campus, which was perfect for drinking, was used in this test.
- Polypropylene Fibers:(SYNTHETIC)
High-Quality sheets of easily separable synthetic fibers were used in this test to achieve the maximum and accurate results. The use of synthetic micro and macro-fibers in concrete can often greatly improve the overall durability and long-term performance of concrete structures. Synthetic micro-fibers provide superior resistance to the formation of plastic shrinkage cracks versus welded wire fabric. However, they are unable to provide any resistance to further crack width openings caused by drying shrinkage, structural load or other forms of stress. Synthetic macro-fibers can provide resistance to plastic shrinkage. These products will also provide concrete enhanced toughness and the ability to deliver structural capacity when properly designed. Synthetic macro-fibers can be used as a true alternative to welded wire fabric, steel fibers and light gauge steel rebar for pre-cast, slabs-on-grade and shotcrete applications. It is suitable to increase the impact strength. Possess very high tensile strength, but their low modulus of elasticity and higher elongation do not contribute to flexural strength. Nylon is considered a plastic material, and as such, has not received the growth that steel and synthetic have. Most plastic fibers are believed to contribute little to static strength of concrete; however, nylon and polypropylene can increase the bending and impact strength. These fibers are also naturally alkali resistant.
Procedure:
Now the trial procedure for the first casting was carried out by preparing the first trial slump. However, the first slump could not gain enough strength and was decreased to 10mm. The results were not near to the milestones of achievement, hence, the ACI mix design was revised again, but with the increment in the water-cement (w/c) ratio. The ratio was increased to 0.58. This time, the slump successfully reached the desired outcome and the castings were then processed for preparation. The total number of samples prepared for this test was 78.
The whole procedure initiated with the concept of adding different proportions to every single casting in your team. For that purpose, five different proportions of synthetic fibers were added in the plain concrete mixture per casting. The percentages that were considered are 0.4, 0.6, 0.8, 1.2, 1.6% of the total plain concrete mixture per casting. The castings were settled and examined after 7 and 28 days to record the results of the early and ultimate strengths respectively.
Quantities:
Fiber Quantities
- 0.4%×7000g=28g
- 0.8%×7000g=56g
- 1.2%×7000g=84g
- 1.6%×7000g=112g
- 2% x7000g= 140g
Other
- Cement=7kg
- Sand=12.25kg
- Aggregate=21.56kg
- Water=4.06kg Slump Test:
When the casting procedure was processed, the first slump was composed, without any synthetic fiber addition, as the control slump.
After measuring the slump reduction in the control slump, further readings were noted for the slumps that were processed with different proportions of glass fibers in the concrete. The behavior was observed that whenever the percentage/ proportion of the glass fiber in the concrete was increased, the resultant slump was proportionally decreased. Therefore, the least slump was observed in the slump with 1.6 % of fiber addition in the concrete.
After this analysis, the concrete samples were gone through the process of casting and were left for curing for 14 and 28 days. During and after the curing period, certain essential tests were performed. Those tests were:
- Compressive Strength Test
- Split Tensile Test
- Flexural Strength Test
- Modulus of Elasticity and Ductility
- Water Absorption Test
- Ultrasonic Pulse Velocity Test
These tests were performed during the curing period after 7 and 28 days and the results were observed and noted respectively.
Gallery
More from Civil Engineering
Influence Of Adding Graphite Nano/Micro Platelets On Mechanical And Durability Properties…
In this project Nano-graphite platelets are added in Self compacting concrete (SCC) at different percentages i…
Supervisor: Muhammad Harris Naeem
Effect of Nano/Micro Graphite on Mechanical Properties of Cementitious Concrete with Parti…
Excessive use of natural raw materials is leading to the shortage of these materials in making concrete in th…
Supervisor: Maryum Bilal
Code Based Seismic Design Of Multi-Story buildings In Pakistan
The project involves the design of the four story building (Ground+3) keeping in view the American Concrete In…
Supervisor: Naveed Malik
Effect Of Variation Of Bentonite Content On Mechanical Properties Of Locally Developed Rea…
We varied quantity of bentonite in reactive powder concrete to check the behaviour and strengths of rpc under…
Supervisor: abdullah khan